![]() Noise reduction circuitry improves sensitivity in high absorption regionsĪ unique, Fujifilm innovation in noise reduction circuitry maximizes signal strength to improve image quality in high absorption areas. This design significantly suppresses scattering and attenuation of X-ray signals, improving efficiency to produce sharper images at lower doses compared to traditional designs. Patented ISS capture technology promotes high sensitivityįujifilm’s proprietary Irradiated Side Sampling (ISS) positions its capture electronics (TFTs) at the irradiation side, in contrast to traditional detectors. Virtual Grid intelligent image processing replaces the use of a grid to enhance contrast and improve clarity while reducing dose as much as 50% compared to exams performed with a grid. Intelligent Virtual Grid image processing for situations where grid use can be challenging The resulting first-up images have outstanding detail and greater window and leveling capability in PACS. 3 hours (with battery charger), Approx.Refined Dynamic Visualization image processing produces exceptional imagesįDR D-EVO GL utilizes the latest Fujifilm digital image processing technology, including Dynamic Visualization, which optimizes image display based on recognition of contrast levels throughout the entire exposure field. (2.1 kg) excludes batteryĬycle time: Less than 10 sec (wired), Less than 11 sec (SmartSwitch)īattery recharging time: Approx. Type: Detector with patented ISS (Irradiation Side Sampling) and flexible film-based TFT detector technologyĭetector external size: 18 x 18 x 0.6″ approx. Scintillator: GOS (Gadolinium oxysulfide)ĭetector external size: 18 x15 x 0.6″ approx., (460˜ x 384˜ x 15mm)Ĭycle time: Less than 9 sec (wired), Less than 10 sec (SmartSwitch)īattery recharging time: Approx. Type: Detector with patented ISS (Irradiation Side Sampling) and flexible film-based TFT detector technology Grid cutoff and retakes associated with misalignment of X-ray tube and grid are also prevented.ĭynamic Visualization II: Intelligent feature recognition technology optimizes image qualityĪdvanced algorithms optimize contrast and density based on anatomic definition, hardware and thickness characteristics, resulting in outstanding detail and greater window and leveling capability in PACS. Eliminating the grid improves patient comfort, simplifies positioning and allows as much as 50% lower dose compared to grid exams. Virtual Grid: High quality images without a physical gridĪdvanced processing simulates scatter clean up without a physical grid, correcting for the effects of scatter radiation while retaining contrast and sharpness. The additional capabilities of Memory Mode and Smart Switch bring added value for emergency, on-demand backup and failsafe uses with any portable, room or even for remote off-site and disaster response uses. Digital readout on detector face tracks images stored and increments as they are acquired.įDR D-EVO III’s unique combination of form and function brings significant value to traditional room retrofit and mobile uses. Images are retained even if detector power is interrupted. Suitable for outdoor use during disaster response.ĭedicated memory mode enables added emergency uses. Suitable for outdoor use with an expanded spectrum This eliminates concerns about battery life or on-demand battery swaps even in the midst of critical care. The battery can easily be replaced with one hand and the detector can be back up and ready in ~90 seconds. The granularity and visibility of dense, low penetration or ultra low dose regions are improved. Uniquely engineered noise reduction circuitry reduces noise in the image to improve signal strength. ![]() Increased x-ray absorption is achieved through our uniquely formulated scintillator layer, which employs photographic film technology to optimize the blending ratio of phosphor particles to minimize blur and enhance sharpness.įujifilm’s noise reduction circuitry improves detector sensitivity in high absorption and low dose images Unique formulation of large and small phosphor particles at a optimal ratios, enhances x-ray absorption ![]() This design suppresses scattering and attenuation of x-ray signals, to produce sharper images at lower doses compared to traditional designs. Patented ISS capture technology promotes high sensitivityĮquipped with Fujifilm’s patented Irradiated Side Sampling (ISS) technology which bonds its capture electronics (TFTs) to the x-ray irradiation side, in contrast to traditional detectors. Features Fujifilm’s exclusive technologies for achieving high resolution and low dose
0 Comments
Leave a Reply. |